GE ZIR36N LH 用户手册

下载
页码 40
4
For a complete food storage center,
install a Monogram Freezer and
Refrigerator side by side. Order ZUG75
Unified Grille Panel Kit for one 
continuous 3/4
″ panel. 
• Electrical and water locations must 
be located as shown for either type 
of installation. A separate 115V, 
60Hz. 20 amp power supply is
recommended for each product.
NOTE: Additional cutout width may be
required when side panels are used. Add
side panel thickness to the finished cutout to
calculate rough-in width. See installation
examples below.
*72
″ min. for a flush installation
71-1/2
″ min. for a semi-flush installation
Side panels are required whenever the sides of the
product will be exposed.
1/2
″ to 3/4″ side panels are normally set into place
and fastened to adjacent cabinetry or back wall
before rolling the refrigerator or freezer into the
opening.
Therefore, the rough-in dimensions must allow 
for side panel thickness. In a flush and semi-flush
installation, the finished dimension (width of the
opening after side panels are installed) must
accommodate the full width of the product. 
See page 11 for side panel sizes.
Side By Side
Installation
Of Freezer
And Refrigerator
Installation
Examples
5"
Water Supply
3-1/2"
3-1/2"
5"
10"
10"
3-1/2"
2-1/2"
75" From Floor
to Bottom
of Electrical 
Area
84-1/2" max
83-1/2" min
Finished
Opening
*Finished Width
Electrical 
5"
24-3/4" Total
Depth
Wall View
6"
5"
6"
28-1/2"
Freezer
Refrigerator
Clearances
Factory set for a 130° door swing. Order WX14X99
adjustable door stop to reduce swing to as little as 90°. 
When Installed into a corner:
Allow 25
″ for a full 130° door swing. Allow 15″ for pan
removal. Allow 4
″ min. clearance when door swing is
adjusted to a 90° opening for pan access, but pan
removal is restricted.
Clearances for two products installed side-by-side
with the same (left or right) door swing 
Allow 2
″ minimum clearance between the products to 
prevent door swing interference. Order the WX14X99
adjustable door stop to reduce the factory set 130°
door swing. Allow 15
″ minimum to a wall to achieve
full drawer extension and pan removal. Additional
clearances are required when using custom handles
and panels. 
NOTE: ZUG75 Grille Panel Kit will not fit this
installation.
25"
Min. to
Wall
130
°
130
° Door
Swing
36-3/4"
4" Min.
to Wall
90
° Door Swing
25"
Min. to
Wall
0"
25"
Min. to
Wall
130
° Door
Swing
130
° Door
Swing
2"
15"
5"
Clearances for Multiple Single Door Installations
In a side-by-side installation of a left and right door
swing product, no clearance between the units is
required. If you are installing 3/4
″ thick custom
panels, order ZUG75 Unified Grille Panel Kit for 
one continuous grille panel. 
Clearances for two products installed side-by-side
with right and left side hinges together
Allow 5
″ minimum between the two products to
prevent one door from striking the other. Use the
WX14X99 adjustable door stop to reduce the factory
set 130° door swing and to allow pan removal.
Additional clearances are required when using
custom handles and panels.
NOTE: ZUG75 Grille Panel Kit will not fit this
installation.
DESIGN
INFORMA
TION
Design Information
36
″ Refrigerators, Freezers