Dacor EF42BDCB 用户手册

下载
页码 3
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
11.2
42” & 48” wide
built-In refrigerator
Ef42bDCb, Ef42bNDb, If42bDCb, If42bNDb, 
Ef48bDCb, Ef48bNDb, If48bDCb, If48bNDb
112905
1/3
Model
Rough-In Width “A”
42-Inch
41 1/2”” (1054mm)
48-Inch
47 1/2”” (1207mm)
D
oor
 s
winG
 D
imEnsions
The area to the left and the right of the appliance must permit 
both doors to open to a minimum of 90°. Allow a minimum of 2 
1/2” (64mm) space between the side of the refrigerator doors and 
a corner wall.
NOTE: More clearance may be required if using an overlay panel 
or custom handles.
p
roDuct
 D
imEnsions
◊ 
The depth from the front of the top grill (w/o decorator panel) 
to the back of the refrigerator chassis is 25 1/4” (641mm).
◊ 
The depth from the rear of the top grill to the back of the 
refrigerator chassis is 23 13/16” (605mm).
◊ 
The power cord is 40” (1016mm) long.
◊ 
The height from the top of the top grill to floor with the 
leveling legs in the down position is 83 3/8” (2118mm) 
◊ 
The height from the top of the top grill to floor with the 
leveling legs in the fully extended position is 84 5/8” 
(2149mm) 
◊ 
The chassis width from the chassis edge to the chassis edge 
for 42-inch is model 41 1/4” (1048mm), 48-inch is model 47 
1/4” (1200mm).
◊ 
The overall width from the trim edge to the trim edge for 42-
inch model is 42 1/16” (1068mm), 48-inch model is 48 1/16” 
(1221mm).
E
lEctrical
 r
EquirEmEnts
A 115VAC, 60 Hz, 15 Amp circuit breaker and electrical supply are 
required. A separate dedicated non-GFCI circuit, servicing only 
this appliance, is required.
Your Dacor
®
 Built-In refrigerator is equipped with a 40” (1016mm) 
3-prong grounded power cord, which must be plugged into a 
3-prong grounding-type non-GFCI wall receptacle. Follow the 
National Electrical Code and local codes and ordinances when 
installing the receptacle. See “Rough-In Dimensions” for location 
of the electrical supply.
IMPORTANT: A ground fault circuit interrupter (GFCI) is not 
recommended and may cause interruption of operation.
◊ 
All installations must meet local plumbing code 
requirements.
◊ 
Connect to 1/4” (6mm) copper line to the house cold fresh 
water supply.
◊ 
Use a shut off valve between the refrigerator and supply. 
The shut off valve should be a drilled saddle valve.
◊ 
Do not use a self-tapping valve which reduces water flow 
and clogs more easily.
◊ 
Route the water line within 3-1/2” (89mm) of the rear wall 
and no higher than 3” (76mm) from the floor. 
◊ 
Allow a minimum of 24” (610mm) dimeter service loop of 
copper tubing outside the wall or floor for easy connection to 
the water supply.
Cold water supply
Connect the ice maker to a cold water line with water pressure 
between 30 and 120 PSI. If you have any questions about your 
water pressure, call your utility company.
IMPORTANT:
◊ 
In homes with a Reverse Osmosis water treatment system, 
remove the water inlet connector from the “yellow” valve 
and attached to the “blue” valve. Make sure the water filter 
bypass plug is in place.
w
atEr
 s
upply
 r
EquirEmEnts
7”
4”
2”
6”
3”
75 1/2”
“A”
83 3/4”
Water Supply
Electrical
24”