U-Line 2275ZWC 用户手册

下载
页码 20
2275ZWC & 2275ZWCOL
5
Dual Temperature Zones
Your unit has been designed to provide two temperature 
zones (top and bottom) in the cabinet. Each zone can be 
adjusted within the 4 following temperature ranges:
Note: These are product temperatures, not air 
temperatures.
WINE CAPTAIN TEMPERATURE RANGES
Default
Range
RW (Red Wine)
55°F
60° - 50°F
WW (White Wine)
50°F
55° - 45°F
SW (Sparkling Wine)
45°F
50° - 40°F
BV (Beverage)
38°F
60° - 34°F
Figure 4. Temperature Display 
Temperature Display
The electronic control is configured to show a single 
temperature continuously in each display (Figure 4)
ADJUSTING SET-POINT TEMPERATURE
IMPORTANT
IMPORTANT
Adjust the set-point temperature and wait 24 hours 
for the temperature to stabilize before rechecking.
.
Figure 5. Adjusting Set-Point Temperature
This default temperature is used by the controller to 
maintain the temperature zones in your unit. 
The default temperatures are a recommendation. If 
further temperature adjustments are required, use the 
following procedure to adjust the set-points.
1. Press and release the desired zone WARMER icon to 
put the controller in the SET TEMPERATURE mode. The 
current range symbol will show on the display (top, 
Figure 5)
.
Note: If no further action is taken, this mode will self 
cancel in five seconds, and the original set-point 
temperature will be displayed.
2. Press the WARMER or COOLER icon to scroll to the 
desired range (RW, WW, SW, BV).
3. When the desired range is displayed, press the LIGHT 
icon to display the current set-point temperature 
(bottom, Figure 5).
4. Press the WARMER or COOLER icon as required to 
adjust the set-point temperature.
5. When the desired set-point is displayed, press the LIGHT 
icon. The new set-point will show in the display.
6. Repeat for other zone display if required.
IMPORTANT
IMPORTANT
Whenever a zone range is changed (example: RW to 
WW), it will revert to the factory default.
DISPLAYING ACTUAL ZONE TEMPERATURE
To display actual zone temperatures (not set-point):
1. Press and hold the WARMER icon for the desired zone 
for approximately five seconds until unit beeps, and 
release when the decimal in the display begins to flash 
(Figure 6).
2. The display will show the actual zone temperature.
3. After five seconds, the display will return to the set-
point temperature.
Figure 6. Displaying Zone Temperature
UPPER ZONE CONTROLS
ULIN_1001_A
LOWER ZONE CONTROLS
Light
Display
Power
Warmer
Warmer
Cooler
Cooler
Display
ULIN_1009_A
ULIN_1012_A
LOWER ZONE CONTROLS
Light
Display
Power
Warmer
Warmer
Cooler
Cooler
Display
UPPER ZONE CONTROLS
LOWER ZONE CONTROLS
Light
Display
Power
Warmer
Warmer
Cooler
Cooler
Display
ULIN_1011_A
UPPER ZONE CONTROLS
LOWER ZONE CONTROLS
Light
Display
Power
Warmer
Warmer
Cooler
Cooler
Display