Initial Start-Up
When power is applied to the unit, the control will 
briefly display all symbols, and the Compressor 
symbol will be displayed (if unit is calling for cooling).  
There may be a brief delay prior to the evaporator 
and condenser fans turning on.
Normal System Cycle
After the bottle probe has reached the set point (all 
units are shipped with the set point of 55°F and a 
differential of 1°F).  The WHM is an adjustable fea-
ture which allows the customer the convenience of 
managing the humidity enhancement of their wine 
cellar.  The WHM is one of the many Customer Prefer-
ence Selection features which allow the customer the 
ability to fine tune the controls. This feature is set to 0 
when shipped but if needed can be adjusted.
Anti Short Cycle
The Anti Short Cycle ensures that the unit will remain 
off for a period of 5 minutes after the unit has reached 
the set point to allow the pressure in the refrigeration 
system to equalize prior to starting the compressor.
Defrost Cycle
The Defrost Cycle is a precautionary measure, as icing 
or frosting of the coil does not occur during normal 
operation.   The system will go through a defrost cycle 
every 4 hours.  During the defrost cycle, the in-cellar 
fan will provide air flow across the in-cellar coil, which 
will evaporate any frost accumulation.  
Bottle Probe Failure Protection                                                              
In the event that a bottle probe should fail, the APST 
(Advance Product Safety Technology) will automati-
cally transition the Refrigeration Compressor cycles 
to a pre-determined time series (based on detailed 
laboratory testing), which will ensure that the prod-
uct is kept within the safe range.  