True Manufacturing Company TD-50-18-S-LT 用户手册

下载
页码 23
............ www.truemfg.com ............
INSTALLATION /  OPERATION INSTRUCTIONS
True Food Service Equipment, Inc.
5
5
TOOLS REQUIRED:
•  Phillips screw driver
•  3/8” socket or 3/8” wrench
Step 2
A.
  Use a phillips screw diver and remove four 
screws from the L-bracket connected the unit 
to the wood skid (see image 1).  Then use a 3/8” 
socket or wrench and remove the L-bracket 
from the unit (see image 2).
When lifting unit do not use the countertop as 
a lifting point.  Also remember to leave cabinet 
upright for 24 hours before plugging 
into power source. 
B.  Remove skid by unscrewing all base rail anchor 
brackets.  Place skid to the side.
C.  Carefully upright cabinet.
LOCATING
(Image 1)
Removing 
bracket from 
skid.
(Image 2)
Removing  
bracket from 
cabinet.
Step 3
A.  
Set unit in its final location. Be sure there is 
adequate ventilation in your room.  Under extreme 
heat conditions, (100°F+, 38°C+), you may want to 
install an exhaust fan.
Warning
Warranty is void if ventilation is insufficient.
B.  Proper leveling of your True cooler is critical to 
operating success (for non-mobile models). Effective 
condensate removal and door operation will be 
effected by leveling.
C.  The cooler should be leveled front to back and 
side to side with a level. 
D.  Ensure that the drain hose or hoses are 
positioned in the pan.
E.  Free plug and cord from inside the lower rear of 
the cooler (do not plug in).
F.  The unit should be placed close enough to the 
electrical supply so that extension cords are never 
used.
Warning
Compressor warranties are void if the unit is more than 
7 ft. (2.1m) from plug-in connection or an extension 
cord is used to connect unit to a power supply.