Venting Options
The downdraft vent is shipped with the  
discharge outlet pointing straight down 
and can be changed to a left- or right-side 
discharge. For even more flexibility, the entire 
blower and mounting plate can be adjusted 
3-1/2" to the left or right sides.
ZVB36SH/BH/WH – GE Monogram 36" Telescopic Downdraft Vents
Specification Created 10/03 
130656
Electrical and Gas Locations
Plan the placement of the electrical outlet 
and gas (if used) carefully. Gas or electrical 
outlets cannot be located on the back wall of 
the cabinet because they may interfere with 
the downdraft plenum. 
•  Install a standard electrical outlet within 
reach of the vent’s two-foot-long power 
cord. Locate the outlet inside the cabinet  
on the right side wall. 
•  If the vent is installed in combination with a 
Monogram
®
 gas cooktop, it may operate  
from the same 120V standard duplex outlet.
•  If the vent is installed in combination with a 
Monogram electric cooktop, the vent must 
operate from a separate 120V outlet.
682Dia49
Discharge Down
(As Supplied)
682Dia50
Discharge Left
682Dia51
Discharge Right
34" for 36" Models
28-1/2" for 30" Models
29-1/2"
Electrical
Outlet
12" Above
Cabinet Floor
Do Not Locate Gas or Electrical
Connections Within Shaded Area
682Dia47
For answers to your Monogram,
®
 GE Profile
 or  
GE
®
 appliance questions, visit our website at  
GEAppliances.com or call GE Answer Center
®
  
service, 800.626.2000.