VENTING   REQUIREMENTS
Determine which venting method is best for your application.  
Ductwork can extend either through the wall or the roof.
The length of the ductwork and the number of elbows should 
be kept to a minimum to provide efficient performance.  The 
size of the ductwork should be uniform.  Do not install two 
elbows together.  Use duct tape to seal all joints in the ductwork 
system.  Use caulking to seal exterior wall or floor opening 
around the cap.
Flexible ductwork is not recommended.  If it is used, each foot 
of flexible ductwork used is equivalent to two feet of straight 
metal ductwork when calculating the ductrun length.  Thus, 
a flexible elbow equals two standard elbows.
Make sure there is proper clearance within the wall or floor 
for exhaust duct before making cutouts.  Do not cut a joist or 
stud unless absolutely necessary.  If a joist or stud must be 
cut, then a supporting frame must be constructed.  
WARNING - To Reduce The Risk Of Fire, Use Only Metal 
Ductwork.
ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz AC-only electrical supply is required on 
a separate 15 amp circuit, fused on both sides of the line.  
A time-delay fuse or circuit breaker is recommended.  The 
fuse must be sized per local codes in accordance with the 
electrical rating of this unit as specified on the serial/rating 
plate located inside the unit near the field wiring compartment.  
THIS UNIT MUST BE CONNECTED WITH COPPER WIRE 
ONLY.  Wire sizes must conform to the requirements of the 
National Electrical Code, ANSI/NFPA 70 - latest edition, and 
all local codes and ordinances.  Wire size and connections 
must conform with the rating of the appliance.  Copies of the 
standard listed above may be obtained from: 
 
National Fire Protection Association
 
Batterymarch Park
 
Quincy, Massachusetts  02269
Version 11/98 - Page 2
• Venting system MUST terminate outside the 
home.
• DO NOT terminate the ductwork in an attic or 
other enclosed space.
• DO NOT use 4" laundry-type wall caps.
• Flexible-type ductwork is not recommended.
• DO NOT obstruct the flow of combustion and 
ventilation air.
• Failure to follow venting requirements may result 
in a  fire.
This  appliance  should  be  connected  directly  to  the  fused 
disconnect (or circuit breaker) through flexible, armored or 
nonmetallic sheathed copper cable.  Allow some slack in the 
cable so the appliance can be moved if servicing is ever nec-
essary.  A UL Listed, 1/2" conduit connector must be provided 
at each end of the power supply cable (at the appliance and 
at the junction box).
When making the electrical connection, cut a 1   1/4" hole 
in the wall.  A hole cut through wood must be sanded until 
smooth.  A hole through metal must have a grommet. 
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI-
CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE 
FOLLOWING:  Use this unit only in the manner intended 
by the manufacturer.  If you have any questions, contact 
the  manufacturer.    Before  servicing  or  cleaning  unit, 
switch off power at service panel and lock service panel 
to prevent power from being switched on accidentally.  
When the service disconnecting means cannot be locked, 
securely fasten a prominent warning device, such as a 
tag, to the service panel.
Installation Work And Electrical Wiring Must Be Done By 
Qualified Person(s) In Accordance With All Applicable 
Codes And Standards, Including Fire-Rated Construction.  
When cutting or drilling into wall or ceiling, do not dam-
age electrical wiring and other hidden utilities.  Ducted 
fans must always be vented to the outdoors.
Sufficient  air  is  needed  for  proper  combustion  and 
exhausting of gases through the flue (chimney) of fuel 
burning equipment to prevent backdrafting.  Follow the 
heating equipment manufacturer's guideline and safety 
standards such as those published by the National Fire 
Protection Association (NFPA), and the American Society 
for Heating, Refrigeration and Air Conditioning Engineers 
(ASHRAE), and the local code authorities.
CAUTION:  For  General  Ventilating  Use  Only.    Do  Not 
Use To Exhaust Hazardous  or  Explosive Materials and 
Vapors.
   WARNING
• Electrical ground is required on this rangehood.
• If cold water pipe is interrupted by plastic, 
nonmetallic gaskets or other materials, DO NOT 
use for grounding.
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the neutral or grounding 
circuit.  A fuse in the neutral or grounding circuit 
could result in electrical shock.
• Check with a qualified electrician if you are in doubt 
as to whether the rangehood is properly grounded. 
• DO NOT use this appliance with any solid state fan 
speed control device.
• Failure to follow electrical requirements may result 
in a fire.   
   WARNING
!
!