4. Attach 1 undercounter bracket on front upper right corner of 
downdraft vent with slot over vent mounting hole and flange 
against countertop. Attach other bracket to left side of the 
downdraft vent. Drill starter holes through undercounter 
mounting brackets into the underside of the countertop. 
Insert appropriate length screws into holes and tighten 
brackets to countertop.
Make Electrical Connections
1. Disconnect power.
2. Feed the power supply cable through the conduit connector 
and into the terminal box.
3. Attach the green (or green and yellow) ground wire to the 
green ground screw. Tighten the conduit connector clamp 
screws.
4. Connect the 2 white wires together using UL listed wire 
connectors. 
5. Connect the 2 black wires together using UL listed wire 
connectors.
6. Replace the terminal box cover and secure with screw.
7. Reconnect power.
Check Operation
1. Push and hold the button on the top of the downdraft vent for 
a few seconds. The retractable section of the downdraft vent 
will rise, and the blower will start. Position the top trim over 
the retractable section and snap trim into place.
Trim kits for matching your cooktop color are available from 
your dealer.
For information on ordering, see the “Assistance or Service” 
section.
2. Slide the control slider on the side of vent to check the 
operation and speed of the blower.
3. If the blower does not operate:
Check that filter or filters are pressed in as far as they will 
go.
Check that the circuit breaker has not tripped or a 
household fuse blown.
Check downdraft fuse located under power board.
4. Connect vent system to blower. Vent system must end with a 
wall or roof cap. Use clamps to seal all joints.
A. When attaching undercounter bracket to underside 
of countertop, make sure that the screw length will 
not go through countertop when tightened.
B. Backsplash
C. Countertop
A
B
C
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in 
terminal box.
Failure to do so can result in death, fire, or 
electrical shock.
A. Green or green and yellow ground wire
B. Green ground screw
C. White wires
D. UL listed wire connectors
E. Black wires
F. UL listed or CSA approved conduit connector
G. Downdraft vent wiring
A. Top trim
B. ON/OFF button
C. Blower control slider
D. End cap
E. Filters
A
B
C
D
E
F
G
A
B
D
E