Manitowoc SN12/SN20 Model Nugget Ice Machines 
 
 
 
            
 Cutter Head Replacement Instructions 
 
 
1.  Disconnect water supply. 
2.  Remove front panel. 
3.  Move toggle switch to CLEAN position after the 5 minute delay expires. The evaporator and float 
chamber will drain. 
4.  Disconnect power at electrical disconnect. 
 
5.  Remove top, left and right side panels. 
6.  Remove ice chute assembly. 
NOTE; if the ice wiper can not be hand removed; place the handle end of a screwdriver against the ice 
wiper, then tap the screwdriver (counterclockwise) with a hammer to loosen the ice wiper from the 
auger. 
 
 
 
 
 
 
 
 
WARNING
 
Disconnect power to the ice machine at the electrical disconnect, moving 
the toggle switch to the off position will not disconnect line voltage. 
Manitowoc Foodservice 
2110 South 26
th
 Street, P.O. Box 1720, Manitowoc, WI  54221-1720 USA 
 
 
 
 
 
 
000004021 
Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879 
 
 
 
Sheet 1 of 2  
Web Site - 
www.manitowocice.com
  
 
 
 
 
 
 
 
 
 
08/25/08 
REMOVE ICE DAMPER  
REMOVE COVER  
REMOVE STRAINER 
REMOVE ICE WIPER 
LOOSEN HOSE CLAMP AND 
DISCONNECT DRAIN LINE
REMOVE ICE CHUTE