G-0400 REFRIGERANT FIELD 
CONVERSION PROCEDURE 
R-502 to R-402B 
FOR MODELS
 
 
GR-0400A     GR-0401W    GR-0490N       
GD-0402A    GD-0403W    GD-0492N 
GY-0404A    GD-0405W    GY-0494N 
 
 
WARNING! 
Use only R-402B as 
retrofit refrigerant.  Other 
replacement refrigerants 
may cause poor performance 
and/or component failure.
 
EQUIPMENT MODIFICATION REQUIREMENTS
 
                               
           
Component                                                                    Change Required 
Compressor 
 
 
 
None (replacement compressor is precharged with POE oil) 
Expansion Valve (TXV) 
 
 
None          
High Pressure Cut-out 
 
 
None 
Low Pressure Cut-out (Remotes) 
 
None 
Fan Cycling Control (Air-cooled) 
 
None 
All Solenoid Valves 
 
 
None 
Water Regulating Valve (Water-cooled) 
None  
Heat 
Exchanger 
   None 
Electrical 
Wiring 
   None 
Branch Circuit Fuse Size   
 
None 
Air-cooled 
Condenser 
  None 
Water-cooled 
Condenser 
  None 
Evaporator 
   None 
SYSTEM PERFORMANCE AFTER CONVERSION
 
 
        Daily Ice Production                  Energy Efficiency 
 
        G-0400  8% increase                     5% increase 
 
 
Operating discharge (high) pressure:  air-cooled models will run 20-30  psig (138-207 kPa gauge) 
higher than R-502 pressures published in service manuals.  Set water-cooled head pressure the same 
as R-502 settings.
 
 
Operating suction (low) pressure:  will run 1-3 psig (7-21 kPa gauge) higher than R-502 pressure 
published in service manuals.
 
 
 