Hoshizaki SRH/3 KM-1400SWH-M 用户手册

下载
页码 101
71
12. KM-1601SWH3
SPECIFICATION SHEET
AC SUPPLY VOLTAGE
208-230/60/3
AMPERAGE
9.0 A (5 Min. Freeze AT 104°F/WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
    ELECTRIC    W  (kWH/100 lbs.)
2390(3.66)
2270(3.5)
    WATER   gal./24HR (gal./100 lbs.)
372(23.8)
804(51.7)
    WATER COOLED CONDENSER
1565(100)
910(59)
gal./24HR (gal./100 lbs.)
ICE PRODUCTION PER CYCLE
30.2  lbs. (13.7 kg) 1440 pcs.
REFRIGERANT CHARGE
R-404A,  3 lbs. 1 oz.  ( 1400g )
PERFORMANCE DATA SHEET
70/21
1555
705
1558
707
1466
665
80/27
1557
706
1562
708
1417
643
90/32
1558
707
1565
710
1440
653
lbs./day   kg./day
100/38
1507
684
1536
697
1326
601
70/21
80/27
90/32
watts
100/38
70/21
1714
6.49
1779
6.73
2186
8.28
80/27
1764
6.68
1866
7.06
2449
9.27
90/32
1779
6.73
1937
7.33
2455
9.29
gal./day    m3/day
100/38
2013
7.62
2059
7.79
2930
11.09
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
239
16.8
241
16.9
257
18.1
80/27
240
16.9
244
17.1
268
18.8
90/32
241
16.9
246
17.3
267
18.8
PSIG     kg/cm2G
100/38
249
17.5
251
17.6
287
20.2
70/21
41
2.9
42
3.0
45
3.2
80/27
42
2.9
44
3.1
47
3.3
90/32
42
3.0
45
3.2
48
3.4
PSIG     kg/cm2G
100/38
43
3.0
46
3.2
51
3.6
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3,200 BTU/h  [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER
111 gal./h  [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE
less than 10 PSIG
3.8
2.4
2.0
HEAD PRESSURE
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER
23,500 BTU/h  [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
HARVEST CYCLE TIME
6.0
4.9
4.4
5.2
3.6
3.6
4.9
2.4
2.2
27
24
26
28
25
26
30
2303
2395
2430
APPROXIMATE WATER 
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
24
24
26
24
25
APPROXIMATE ELECTRIC 
CONSUMPTION
2270
2305
2332
2297
2351
2367
2305
2390
2411
APPROXIMATE ICE 
PRODUCTION PER 24 HR.
AMBIENT TEMP. 
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
ENG.F-011.1.0205