Hoshizaki SRH/3 KM-1400SWH-M 用户手册

下载
页码 101
81
22. KM-1900SWH3
SPECIFICATION SHEET
AC SUPPLY VOLTAGE
208-230/60/3
AMPERAGE
8.4 A (5 Min. Freeze AT 104°F/WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
    ELECTRIC    W  (kWH/100 lbs.)
2490(3.3)
2410(3.2)
    POTABLE WATER   gal./24HR (gal./100 lbs.)
341(18.8)
584(32.0)
    WATER COOLED CONDENSER
1796(99)
982(54)
gal./24HR (gal./100 lbs.)
ICE PRODUCTION PER CYCLE
45.4 lbs. (20.6 kg)   2160pcs.
REFRIGERANT CHARGE
R404A, 3 lb. 1.4 oz.  (1400g)
PERFORMANCE DATA SHEET
70/21
1825
828
1822
826
1693
768
80/27
1823
827
1818
824
1619
734
90/32
1822
826
1814
823
1642
745
lbs./day   kg./day
100/38
1754
796
1774
805
1484
673
70/21
80/27
90/32
watts
100/38
70/21
1566
5.93
1733
6.56
2144
8.12
80/27
1693
6.41
1953
7.39
2465
9.33
90/32
1733
6.56
2137
8.09
2615
9.90
gal./day    m3/day
100/38
2063
7.81
2249
8.51
3054
11.56
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
239
16.8
241
16.9
255
17.9
80/27
241
16.9
244
17.1
264
18.5
90/32
241
16.9
246
17.3
264
18.5
PSIG     kg/cm2G
100/38
248
17.4
250
17.6
280
19.7
70/21
50
3.5
50
3.5
51
3.6
80/27
50
3.5
50
3.5
52
3.6
90/32
50
3.5
50
3.5
52
3.6
PSIG     kg/cm2G
100/38
51
3.6
50
3.5
53
3.7
27,100  BTU/h  [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3,200 BTU/h  [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER
117 gal./h  [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE
       less than 10 PSIG
APPROXIMATE ICE 
PRODUCTION PER 24 HR.
AMBIENT TEMP. 
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
APPROXIMATE ELECTRIC 
CONSUMPTION
2410
2433
2461
2428
2464
2489
2433
2490
2516
2437
2496
2540
APPROXIMATE WATER 
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
32
33
35
32
34
37
33
34
38
34
35
41
HARVEST CYCLE TIME
4.7
4.1
3.9
4.2
3.4
3.5
4.1
2.7
2.7
3.5
2.7
2.7
HEAD PRESSURE
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER
ENG.F-011.1.0205