Hoshizaki SRH/3 KM-1400SWH-M 用户手册

下载
页码 101
86
27. KM-2100SWH3
SPECIFICATION SHEET
AC SUPPLY VOLTAGE
208-230/60/3
AMPERAGE
10.5 A (5 Min. Freeze AT 104°F/WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
    ELECTRIC    W  (kWH/100 lbs.)
2860(3.35)
2740(3.14)
    POTABLE WATER   gal./24HR (gal./100 lbs.)
410(20.0)
673(32.1)
    WATER COOLED CONDENSER
1948(95)
1121(54)
gal./24HR (gal./100 lbs.)
ICE PRODUCTION PER CYCLE
46.8 lbs. (21.2 kg)   2160pcs.
REFRIGERANT CHARGE
R404A, 3 lb. 6.7 oz.  (1550g)
PERFORMANCE DATA SHEET
70/21
2096
951
2083
945
1927
874
80/27
2086
946
2065
937
1834
832
90/32
2083
945
2050
930
1848
838
lbs./day   kg./day
100/38
2005
910
2003
908
1662
754
70/21
80/27
90/32
watts
100/38
70/21
1794
6.79
1959
7.42
2226
8.43
80/27
1920
7.27
2176
8.24
2466
9.33
90/32
1959
7.42
2358
8.92
2643
10.00
gal./day    m3/day
100/38
2225
8.42
2424
9.18
2905
11.00
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
244
17.2
248
17.4
264
18.6
80/27
247
17.4
254
17.8
275
19.4
90/32
248
17.4
258
18.1
278
19.5
PSIG     kg/cm2G
100/38
255
17.9
263
18.5
296
20.8
70/21
48
3.4
48
3.4
49
3.5
80/27
48
3.4
49
3.4
50
3.5
90/32
48
3.4
49
3.4
50
3.5
PSIG     kg/cm2G
100/38
49
3.4
49
3.5
51
3.6
31,100 BTU/h  [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3,800 BTU/h  [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER
109 gal./h  [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE
       less than 10 PSIG
3.8
3.1
2.7
HEAD PRESSURE
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
4.9
4.4
4.0
4.5
3.7
3.6
4.4
3.2
2.9
33
29
31
33
30
31
36
2767
2861
2870
APPROXIMATE WATER 
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
28
29
31
29
30
APPROXIMATE ELECTRIC 
CONSUMPTION
2740
2775
2791
2767
2821
2819
2775
2860
2865
APPROXIMATE ICE 
PRODUCTION PER 24 HR.
AMBIENT TEMP. 
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
ENG.F-011.1.0205