C. Settings and Adjustments
1. Default Dip Switch Settings
The S1 dip switch settings are factory-set to the following positions:
Dip Switch No.
1
2
3
4
5
6
7
8
9
10
DCM-270BAH(-OS) OFF OFF OFF OFF ON OFF OFF OFF OFF OFF
Bin Control Shutdown Delay (infrared sensor)
Continuous Dispensing Timer 
(Do not adjust on DCM-270BAH-OS)
Drain Frequency Control
Bin Control Selector 
Bin Control Shutdown Delay (mechanical) and Periodic Agitation 
of Storage Bin
Normally off (factory use)
2. Bin Control Shutdown Delay (Infrared Sensor) (S1 dip switch 1, 2, 3)
NOTICE
Do not adjust. Setting not used on this model. When dip switch 7 is off, 1, 2, and 3 
are ignored.
Factory set. DCM-270BAH(-OS) does not use a bin control with an infrared sensor.  
The appliance uses a bin control with a mechanical microswitch for ice level control.
3. Drain Frequency Control (S1 dip switch 4)
The appliance is factory set for optimum performance with the 1-in-1 drain cycle (S1 dip 
switch 4 in the "OFF" position). This setting allows for removal of sediment from the 
evaporator without interrupting the icemaking process. 1-in-12 drain cycle is available.
S1 Dip Switch Setting 
Drain Timer Interval Drain Valve Open
No. 4
OFF (1-in-1)
1 Hour
2 Seconds
ON (1-in-12)
11 Hours 45 Minutes
10 Minutes