Installation Instructions
2
3  ElEctrIcal GroundInG 
InstructIons
This  appliance  must  be  grounded.  This  oven  is  equipped  with 
a  cord  having  a  grounding  wire  with  a  grounding  plug.  It  must 
be  plugged  into  a  wall  receptacle  that  is  properly  installed  and 
grounded  in  accordance  with  the  National  Electrical  Code  and 
local  codes  and  ordinances.  In  the  event  of  an  electrical  short 
circuit, grounding reduces risk of electric shock by providing an 
escape wire for the electric current.
WarnInG - Improper use of the grounding plug can result in a 
risk of electric shock.
ElEctrIcal rEquIrEMEnts
The  oven  is  equipped  with  a  3-prong  grounding  plug.  DO  NOT 
UNDER  ANY  CIRCUMSTANCES  CUT  OR  REMOVE  THE 
GROUNDING 
PIN 
FROM 
THE  PLUG.  DO  NOT  USE 
EXTENSION CORD.
The  Power  Supply  Cord  and 
plug  must  be  connected  to  a 
separate  120  Volt  AC,  60  Hz, 
15 Amp, or more branch circuit, 
single grounded receptacle. The 
receptacle  should  be  located 
inside the cabinet directly above 
the  Microwave  Oven  mounting 
location as shown in Figure 2.
notEs:
1.  If  you  have  any  questions  about  the  grounding  or  electrical 
instructions, consult a qualified electrician or serviceperson.
2.  Neither  Electrolux  nor  the  dealer  can  accept  any  liability  for 
damage to the oven or personal injury resulting from failure to 
observe the correct electrical connection procedures.
Opening for 
Power Cord
Figure 2
Ground 
Receptacle
radIo or tV IntErfErEncE
Should there be any interference caused by the microwave oven 
to your radio or TV, check that the microwave oven is on a different 
electrical circuit, relocate the radio or TV as far away from the oven 
as feasible or check position and signal of receiving antenna.
4  Hood EXHaust duct
When the hood is vented to the outside, a hood exhaust duct is 
required. All ductwork must be metal; absolutely do not use plastic 
duct. Check that all connections are made securely. Please read 
the following carefully: 
Exhaust connection: The hood exhaust has been designed to 
connect to a standard 3 Z\v" x 10" rectangular duct. If round duct is 
required, a rectangular-to-round adapter must be used.
rear exhaust: If a rear or horizontal exhaust is to be used, care 
should be taken to align the exhaust with the space between the 
studs,  or  wall  should  be  prepared  at  the  time  it  is  constructed 
by  leaving  enough  space  between  wall  studs  to  accommodate 
exhaust.
Maximum duct length: For satisfactory air movement, the total 
duct length of 3 Z\v" x 10" rectangular or 6" diameter round duct 
should not exceed 140 feet.
Elbows,  adapters,  wall  caps,  roof  caps,  etc.  present  additional 
resistance to air flow and are equivalent to a section of straight duct 
which is longer than their actual physical size. When calculating 
the total length, add the equivalent lengths of all transitions and 
adapters  plus  the  length  of  all  straight  duct  sections.  Figure  3 
shows the approximate feet of equivalent length of some typical 
ductwork parts. Use the values in parentheses for calculating air 
flow resistance equivalent, which should total less than 140 feet.
90˚ ELBOW (10 FT.)
45˚ ELBOW (5 FT.)
ADAPTOR (5 FT.)
90˚ ELBOW (25 FT.)
45˚ ELBOW (5 FT.)
WALL CAP (40 FT.)
ROOF CAP (24 FT.)
10" WIDE ELBOW (10 FT.)
Figure 3
5  tools rEcoMMEndEd for 
InstallatIon
•  Phillips Screwdriver
•  Electric Drill
•  Z\₂", ⁵\₈" and ³\₃₂" Drill Bits
•  1 Z\₂" Wood Bit or Metal Hole 
Cutter (if metal cabinet is 
used)
•  Saw to cut exhaust opening 
(if needed)
•  Protective Drop Cloth for 
product and range - you may 
also use carton for protection
•  Scissors
•  Pencil
•  Measure
•  Tape