Figure 2A
Control Set for 230 Volts AC Line Input
(Factory Setting)
(Jumper J1 in the "230V" Position)
Figure 2B
Control Set for 115 Volts AC Line Input
(Jumper J1 in the "115V" Position)
1-2. Motor  Frequency  Selection  (Jumpers  J1  and  J2,  on  the  Lower  PC  Board):    The  controls  are  factory  set  to
operate 60 Hz motors (Jumper J1 factory set to the "60Hz" position and Jumper J2 factory set to the "X1" position).
To operate 50 Hz motors, set Jumper J1 to the "50Hz" position.  (Be sure that Jumper J2 is set to the "X1" position.)
To  operate  120  Hz  motors,  be  sure  that  Jumper  J1  is  set  to  the  "60Hz"  position  and  set  Jumper  J2  to  the  "X2"
position.  To  operate 100  Hz  motors,  set Jumper J1  to  the  "50Hz"  position  and set Jumper J2  to  the  "X2"  position.
See Figure 3 below.
Figure 3 - Motor Frequency Selection (Jumpers J1 and J2)
60 Hz Motor Operation
(Factory Setting)
50 Hz Motor Operation
120 Hz Motor Operation 100 Hz Motor Operation
1-3.
Other Jumpers: For other jumper settings, see the manual.
 $&/LQH)XVLQJ
Install a  fuse  or  circuit  breaker  in the  AC line.    Fuse each  conductor  that  is  not  at  ground  potential.    See  Section  VI,  on
page 19 of the manual.  See Table 2 below.
Table 2 - Fuse Selection Chart
AC Line Voltage
(Volts AC)
Maximum AC Line Current
(Amps AC)
AC Line Fuse
(Amps)
115
22.0
30
230
14.0
20
 7ULPSRW$GMXVWPHQWV
All trimpots have been factory set for most applications, as described in Section IX, on pages 22 - 27 of the manual. The
figure below shows the CL trimpot setting, which will be added to Section IX-E, on page 24 of the manual.  See Mechanical
Specifications and Control Layout, above, for the location of trimpots.  See Figure 4 below.
Figure 4 - CL Settings