Sharp R-530EK 用户手册

下载
页码 44
11
R - 5 3 0 E K
R - 530EW
CK = Check / RE = Replace
SHORT IN POWER CORD
SHORT OR OPENED  WIRING
MAGNETRON
POWER TRANSFORMER
H.V. RECTIFIER ASSEMBLY
HIGH VOLTAGE CAPACITOR
CAVITY TEMPERATURE FUSE 
MAGNETRON TEMPERATURE FUSE 
PRIMARY INTERLOCK SYSTEM
SECONDARY INTERLOCK SWITCH
MONITOR SWITCH
MONITOR FUSE
OVEN LAMP OR SOCKET
COOLING FAN MOTOR
TURNTABLE MOTOR
TOUCH CONTROL PANEL
WRONG OPERATION
LOW VOLTAGE
DIRTY OVEN CAVITY
KEY UNIT
RELAY (RY1)
DEFROST CENTER
FOIL PATTERN ON PWB.
AH SENSOR
Home fuse or circuit breaker blows when 
power cord is plugged into wall receptacle.
Monitor fuse blows when power cord is 
plugged into wall receptacle.
Any letters or indicators do not appear in 
display when power cord is first plugged 
into wall outlet.
Display does not operate properly when 
STOP/CLEAR key is touched. (Buzzer 
should sound and ":" or time of day 
should appear in display.)
Oven lamp does not light when door is 
opened.
Oven lamp does not go out when door is 
closed.
Oven lamp lights but fan motor and 
turntable motor do not operate.
Oven does not go into cook cycle when 
START pad is touched
Oven seems to be operating but little or 
no heat is produced in oven load. (Food 
incompletely cooked or not cooked at all 
at end of cook cycle.)
Oven goes into a cook cycle but 
extremely uneven heating is produced in 
oven load (food).
Oven does not cook properly when 
programmed for P-50/ 50 PERCENT 
mode. (Operates properly on P-HI/ 100 
PERCENT mode.)
Oven goes into Defrost Center but food 
is not defrosted well.
AH sensor does not end during Sensor 
cooking condition. (Oven does not shut 
off after a cup of water is boiling by 
sensor cooking.)
Oven stops at 16 sec. after starting. 
RE RE
A B C D E E F F G H
RE RE CK
I
CK CK CK
J K L M N
TEST PROCEDURE
POSSIBLE CAUSE
AND
DEFECTIVE PARTS
COOKING 
CONDITION
CONDITION
PROBLEM
OFF 
CONDITION
SENSOR
COOKING
CONDITION