AC Line Voltage:
Single phase 120V, 60Hz, AC only 
AC Power Required:
1640W 14.0 amps. (for FGMV173KW, FGMV173KB, FGMV173KQ,
FGMV174KF, FGMV174KM, DGMV174KF)
1500W 13.0 amps. (for CGMV173KW, CGMV173KB, CGMV174KF)
Output Power*:
1000 W
Frequency:
2450 MHz (Class B/Group2)**
Outside Dimensions (including handle):
29  
15
/
16
”(W) x 16 
3
/
8
”(H) x 17 
15
/
16
”(D)
Cavity Dimensions:
21”(W) x 8 
7
/
8
”(H) x 14 
7
/
16
”(D)
Microwave oven Capacity***:
1.7 Cu.Ft.
Cooking Uniformity:
Turntable / Stirrer Fan System
Weight:
Approx. (net) 54 lb, (gross) 64 lb
Work/Night Light:
2 bulbs 20w each (incandescent light bulbs)
Oven Light:
1 bulb 20w (incandescent light bulbs)
SERVICE CALL CHECK
SPECIFICATIONS
Please check the following before calling for service:
  Place one cup of water in a glass measuring cup in the microwave oven and close the door securely.
  Operate the microwave oven for one minute at HIGH 100%.
A  Does the microwave oven light come on?
YES ____
NO ____
B  Does the cooling fan work? (Put your hand on the louver above the Interactive Display.)
YES ____
NO ____
C  Does the turntable rotate? (It is normal for the turntable to turn in either direction.)
YES ____
NO ____
D  Is the water in the microwave oven warm?
YES ____
NO ____
If “NO” is the answer to any of the above questions, 
please check electrical outlet, fuse and/or circuit 
breaker. If they are functioning properly, CONTACT 
YOUR NEAREST ELECTROLUX AUTHORIZED SER-
VICER.
A microwave oven should never be serviced by a 
“do-it-yourself” repair person.
The International Electrotechnical Commission’s standardized method for measuring output wattage. This test method 
is widely recognized. 
**  This is the classification of ISM (Industrial, Scientific and Medical) equipment described in the International Standard CISPR11.
***  Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for holding food is less.
In compliance with standards set by:
FCC 
-  Federal Communications Commission Authorized.
DHHS - 
Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I, Subchapter J.
NHW  
-  Department of National Health and Welfare of Canada.
 
-  This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.
 
-  This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc. for use in 
USA or Canada.
NOTES
1.  If time appearing in the display is counting down 
very rapidly, check Demonstration Mode on page 22 
and cancel.
2.  If the oven is set for more than 40 minutes at 80, 
90 or 100 percent power level, after the fi rst 40 
minutes the power level will automatically adjust 
itself to 70 percent power to avoid overcooking.
OR7_NEW Model_EN-4.indd   25
09.4.28   11:46:27 AM