Hobart CE6HD ML-138011 用户手册

下载
页码 24
– 22 –
Automatic Clean Cycle
NOTE: Before using the auto clean cycle, make sure that the detergent 
pump tube is inserted correctly into the detergent container and that enough 
detergent is available.
  1. Press the Selection Line Button next to the Auto Clean Cycle icon.
  2.  Use the Plus/Minus Buttons to select the clean cycle time and amount 
of detergent to be used. The time and detergent values are preset. 
Select the preset value depending on the level of cleaning needed.
  3. Press the START/STOP Button to begin the clean cycle.
 95°F
R
STOP
NOTE: All components inside the oven cavity, such as the heating elements, racks, rack guides and interior 
glass, can be sprayed with white vinegar or a deliming product.
  1. Spray the entire oven cavity with white vinegar (full strength) and let it stand for 15 minutes. Or use 
a deliming product. When using a deliming product other than white vinegar, follow the directions 
on the product label.
  2. Close the oven door.
  3. Rinse the oven cavity using the automatic clean cycle and set the cycle to "0".
Quick Rinse Cycle
NOTE: The quick rinse cycle is an automatic cycle that does not use 
detergent.This feature can be used to give the oven cavity a quick rinse 
between product uses.
  1. Press the Selection Line Button next to the Auto Clean Cycle icon.
  2. Use the Minus Button to select "0" detergent to be used.
  3. Press and hold the Minus Button until an "R" appears instead of a 
"0".
  3. Press the START/STOP Button to begin the quick rinse cycle.
Deliming the Cavity
Oven cavity deliming should be done on a regular basis. The frequency 
depends on oven use, quality of the local water supply and what type of 
water treatment system is used. Even with the use of a water treatment 
system, periodic deliming of the oven cavity is still required. If lime scale 
build up becomes visibly noticeable, then the oven cavity deliming should 
be performed.
 Deliming should only be performed on a cool oven after a clean 
cycle has occurred.
Preset Automatic Clean Cycle Values
(times may vary depending on automatic cool down)
Level Detergent Dose
Time
Level Detergent Dose
Time
Level Detergent Dose
Time
0
0
0:25
3
15
0:47
6
30
1:12
1
5
0:30
4
20
0:55
7
35
1:20
2
10
0:38
5
25
1:04
8
45
1:29