Viking VGSU103-4B 用户手册

下载
页码 5
18-1/2”
(46.2 cm)
26-7/8”
(68.3 cm) min.
to
29-7/8”
(75.9 cm) max.
26-3/4”
(67.9 cm)
1-5/16” 
(3.3 cm)
3” (7.6 cm)
28-1/16”
(71.3 cm)
Cutout
Opening
18-1/2”
(46.2 cm)
18-3/4”
(47.6 cm)
VGSU103-4B
VGSU163-6B
Cutout width
26-7/8” (68.3 cm) min. to 29-7/8” (75.9 cm) max.
34-3/8” (87.3 cm) min. to 35-7/8” (91.1 cm) max.
Cutout height
2-1/2” (6.4 cm) min.
Cutout depth
18-5/8” (47.3 cm) min. to 20-1/8” (51.1cm) max.
Surface burner rating
Left front
16,000 BTU Nat. (4.8 kW)/15,500 BTU LP (4.65 kW)
Left rear
12,000 BTU Nat. (3.6 kW)/11,500 BTU LP (3.45 kW)
Right rear
8,000 BTU Nat. (2.4 kW)/7,500 BTU LP (2.25 kW)
Right front
6,000 BTU Nat. (1.8 kW)/5,500 BTU LP (1.65 kW)
Center front/rear
N/A
12,000 BTU Nat. (3.6 kW)/11,500 BTU LP (3.5 kW)
COOKING
Professional Built-In Gas 30”/36”W. Cooktop
P L A N N I N G A N D D E S I G N G U I D E
V I K I N G R A N G E . C O M
1 - 8 8 8 - V I K I N G 1
R E L E A S E D 1 2 / 1 / 0 7
© 2 0 0 7 V R C — I N F O R M AT I O N S U B J E C T T O C H A N G E
UTILITY
REQUIREMENTS
GAS
• Shipped natural gas
standard; to field
convert from natural
or LP/Propane, the
orifice spuds and
regulator must be
physically changed.
o Order conversion
kit NK2VGSU to
convert natural
and LPK-3VGSU to
convert to LP
• Accepts standard
residential 1/2”
(1.3 cm) ID gas
service line
• Gas manifold
pressure
o Natural gas 5.0”
W.C.P.
o LP/propane 10.0”
W.C.P.
ELECTRICAL
• 4-foot (121.9 cm)
cord included with
cooktop
• 3-wire with
ground/3-prong plug
• 120 V/60 Hz
• Maximum amp
usage—2.0
PLUMBING
Not applicable
Installation Requirements
ACCESS REQUIREMENTS
VGSU103-4B
30”W. Four-Burner
Cooktop
VGSU163-6B
36”W. Six-Burner
Cooktop
34-3/8”
(87.3 cm) min.
to
35-7/8”
(91.1 cm) max.
33”
(83.8 cm)
18-1/2”
(46.2 cm)
1-1/4”
(3.2 cm)
3” (7.6 cm)
34-1/4”
(87.0 cm)
Cutout
Opening
18-1/2”
(46.2 cm)
18-3/4”
(47.6 cm)
30”W. Cutout
36”W. Cutout
30”W. Cutout w/Downdraft
36”W. Cutout w/Downdraft