Jackson Tempstar GP 用户手册

下载
页码 43
THERMOSTAT ADJUSTMENT PROCEDURE
7
1) Start up unit
2) Allow to fill, and start warm-up
3) Turn thermostat trim screw Counter Clockwise (CCW) 2 full revolutions
4) Allow wash temperature to reach 170
LF on Wash Temperature Gauge
5) Turn thermostat trim screw Clockwise (CW) until flashing Green LED on control board turns off. (The recirculating pump 
will also turn off).
6) To ensure that the trim screw has not been turned too far CW, turn CCW very slowly until Green LED turns on and once
again turn CW very slowly until Green LED goes out.
7) Start normal operation and monitor wash tank temperature.
8) If readjustment is needed repeat steps 5 - 7 until wash tank temperature maintains at 170
LF during idle time.