PREPARATION
1.  Place the light tower in an area free of dirt and debris 
with enough clearance as not to interfere with any 
overhead obstructions. Make sure it is on secure level 
ground with chock blocks underneath each wheel to 
prevent the light tower from rolling.
2.  If the light tower is in the deployed position,  place the 
tower mast into the cradle support (stowed position).  
See Figure 4. Make sure cradle lock/release pin has 
been inserted and the mast is locked. 
Figure 4. Light Tower in Stowed Position
  DANGER
ALWAYS make sure the area above 
light tower is open and clear of 
overhead power lines and other 
obstructions. The tower extends in 
excess of 30 ft. (9 meters). Contact 
with overhead power lines or other 
obstructions could result in equipment 
damage, serious injury or death!
STOWED
POSITION
MAST
LOCK
 NOTICE
The new lamp adapter plate requires no existing lamp 
removal for installation. All lamps can remain in place 
during installation of the adapter plate.
 NOTICE
Only mount the GB2000 on Light Towers that are 
equipped with one of the following ballasts:
•  UNIVERSAL LIGHTING TECHNOLOGIES INC: 
M1000120AC5M
•  PHILIPS LIGHTING ELECTRONICNA : 71A-6592.
SETUP
POWER DISCONNECTION
1.  For LT12D light towers, disconnect the negative cable 
(black) from battery. See Figure 5.
Figure 5. Disconnecting Battery
2.  For MLT series light towers disconnect the 4-pin power 
cable (Figure 6) from the 120 VAC twist-lock receptacle 
on the front panel of the generator.
Figure 6. MLT Power Cable Removal
DISCONNECT
NEGATIVE
BATTERY CABLE
IDLE CONTROL
0
0
0
0
0
HOURS
ON
OFF
WHISPERW
ATT
7KW AC
Model DA-7000SS
7000 WATT
DIESEL POW
ERED AC GEN
ERATOR
STARTER SWITCH
RUN
HEAT
START
STOP
HOUR METER
AC VOLTMET
ER
AC CIRCUIT
BREAKER
120/240V
25A
25A
120V
20A
25A
MLT
LIGHT TOWER
TO BALLAST
COMPARTMENT
4-PIN POWER
CABLE
DISCONNECT