Instructions for the installer 
 
 
2.2  Gas connection 
This appliance is suitable for installation with 
Natural  Gas  or  ULPG  (propane).  Refer  to 
page 12 for the relevant burner pressure and 
 
 
appropriate 
injector 
sizes. 
When 
the 
appliance  is  to  be  connected  to  Natural  Gas 
 
 
then the pressure regulator supplied must be 
 
fitted  to  the  gas  inlet.  A  test  point  (for 
 
checking the gas pressure) is supplied either 
 
with  the  regulator  or  as  a  separate  fitting  in 
 
the case of ULPG (propane) appliances. 
 
Connection  of  the  appliance  to  the  gas 
 
supply  must  be  in  accordance  with  the 
 
requirements  of  AS5601.  A  ½”  BSP 
 
connector  at  the  inlet  is  recommended  and 
 
the gas supply line to the  appliance must be 
 
of  adequate  length  to  allow  sufficient 
 
withdrawal  of  appliance  for  service  or 
 
disconnection and be: 
1.  annealed copper pipe or; 
 
2.  flexible  hose  according  to AS/NZ1869 & 
 
be at least Class “B”, 10 mm diameter. 
The  appliance  must  be  installed  with  provision  to  allow  the  gas  to  be 
turned  off  and  disconnected  for  servicing  and  removal  of  the  appliance 
as required from the gas supply. 
Before  the  appliance  is  operated  make  certain  all  relevant  parts  are 
placed in the correct position. 
When  the  installation  is  completed  the  installation  connections  of 
appliance  will  require  to  be  leak  tested,  the  burner  operating  pressure 
and flame checked and adjusted. 
Warranty service calls do not cover these adjustments! 
To  check  the  operating  pressure  of  the  appliance  it  is  recommended  at 
least 2 large size burners are used. Ensure appliance is secured to wall 
when installation is completed. 
N.G.  The  regulator  supplied  must  be  fitted  to  the  ½  BSP  thread  at  the 
rear  of  the  appliance.  An  approved  manual  shut-off  valve  must  be 
installed.  The  N.G.  regulator  must  be  checked  and  adjusted  to  1.0kPa 
after installation. 
 
ULPG:  Can  be  connected  to  the  inlet  fitting 
directly.  The  pressure  must  be  checked  to 
ensure it is operating at 2.75kPa. A separate test 
point fitting must be installed between the piping 
&  the  appliance  for  the  pressure  to  be  checked 
to ensure it is operating at 2.75kPa.