Maintenance 
6
308612J
Maintenance
Clean Dispensing Valve and 
System Daily
Clean the outside of the valve by wiping with a soft cloth 
dampened with a compatible solvent. 
To remove a hardened particle from the orifice, blow air 
through the orifice from the front. 
Oil Dispensing Valve Daily
Before each use, lubricate with a spray of oil inside the 
protection tube (13) to prevent fluid buildup on these 
parts. Any buildup could damage the valve packings 
(16, 17, 18).
Service
Needle, Seat and Packings
To clean or replace the needle, seat or packings, pro-
ceed as follows:
1. Follow 
Pressure Relief Procedure on page 4.
2. Remove valve housing:
a. Remove cap and spring.
b. Loosen nut.
c. Pull down housing and needle assembly to 
expose needle shaft.
d. Slide needle through air piston to remove. 
3. Remove retaining nut.
NOTICE
Never immerse the entire dispensing valve in solvent. 
Immersing in solvent removes lubricants and can 
damage packings. 
ti16188b
ti16182a
ti16179a
ti16180a
ti16192a
ti16184b