C-BOX 300/310 
 
2.9  SPECIAL NOTES FOR MATRIX READER SETUP 
 
 
CAUTION 
When connected to a C-BOX 3x0 through the 25-pin connector, the 
9-pin Auxiliary port connector on the Matrix reader cannot be used 
for communication (i.e. configuration through VisiSet™). The Matrix 
reader can only be configured through the 9-pin connector inside 
the C-BOX 3x0 and the C-BOX 3x0 must first be configured. see 
the following paragraphs for details. 
 
 
2.9.1 
Preparing C-Box 3x0 for Matrix Reader Communication 
 
This paragraph describes how to configure a C-BOX 3x0 so that a Matrix reader can 
communicate through the C-Box3x0 and also be configured through its Auxiliary 
RS232 interface. 
1.  Open the C-BOX 3x0; 
2. Move 
the 
Configuration Switch from the Normal Operation to the CFG position; 
3.  Connect the 9-pin internal connector of the C-BOX 3x0 to the PC (using a 
crossover cable) and run the Winhost™ configuration tool; 
4. Select 
the 
Connect option to open communications with the C-BOX 3X0 and 
wait until the correct communication speed has been determined; 
5.  From the SCANNER INTERFACE menu, set Auto Connect: Disabled and verify 
Data Source: Main Interface and save the configuration to the C-Box 3x0 (refer 
to Figure 17); 
 
Figure 17 – WinHost Configuration Menu for C-Box 3x0 
6. Return 
the 
Configuration Switch to the Normal Operation position. 