Connecting a Keyboard Wedge Interface
Figure 5-1.  Keyboard Wedge Interface Connection with Y-cable
To connect the keyboard wedge interface Y-cable:
Interface cables vary depending on configuration. The connectors 
illustrated in 
 are examples only. The connectors may be 
different than those illustrated, but the steps to connect the scanner 
remain the same.
1. Turn off the host and unplug the keyboard connector.
2. Attach the modular connector of the Y-cable to the cable interface port on the 
scanner. (See 
3. Connect the round male DIN host connector of the Y-cable to the keyboard port on 
the host.
4. Connect the round female DIN keyboard connector of the Y-cable to the keyboard 
connector.
5. If required, attach the optional power supply to the connector in the middle of the 
Y-cable.
6. Ensure that all connections are secure.
Y-cable
Male DIN Host 
Female DIN Keyboard 
Keyboard