Fujitsu B120 用户手册

下载
页码 68
Setting up the tower server
Installation
A26361-K646-Z102-1-7619
13
3.4.1 Connecting the tower server to the line voltage
The server is equipped with a permanently installed standard power supply.
Two standard designs are available for the power supply. The only difference between them is that
the connection panel is rotated 180°. Since the connection panels are otherwise identical, the
diagrams below show only one of the standard power supplies.
Both designs for the standard power supply can be set for supply voltage ranges 100 V to 125 V or
200 V to 240 V.
!
Before connecting the server to the line voltage, you must always check that the line
voltage range set on the server corresponds to the local line voltage. The marker arrow on
the plug-in unit points to the voltage range set.
100 V - 125 V
200 V - 240 V
a
Ê 
If the wrong line voltage range is set, lift out the plug-in unit with a screwdriver (a), turn it and
replace it.
1
2
Ê 
Connect the power cable to the server's power connector (1) and to a free grounded power
outlet (2).