Lenovo 6445 用户手册

下载
页码 112
To
 
run
 
ServeRAID
 
Manager
 
in
 
Startable
 
CD
 
mode,
 
turn
 
on
 
the
 
server;
 
then,
 
insert
 
the
 
CD
 
into
 
the
 
CD-RW/DVD
 
drive.
 
If
 
ServeRAID
 
Manager
 
detects
 
an
 
unconfigured
 
controller
 
and
 
ready
 
drives,
 
the
 
Configuration
 
wizard
 
starts.
 
In
 
the
 
Configuration
 
wizard,
 
you
 
can
 
select
 
express
 
configuration
 
or
 
custom
 
configuration.
 
Express
 
configuration
 
automatically
 
configures
 
the
 
controller
 
by
 
grouping
 
the
 
first
 
two
 
physical
 
drives
 
in
 
the
 
ServeRAID
 
Manager
 
tree
 
into
 
an
 
array
 
and
 
creating
 
a
 
RAID
 
level-1
 
logical
 
drive.
 
If
 
you
 
select
 
custom
 
configuration,
 
you
 
can
 
select
 
the
 
two
 
physical
 
drives
 
that
 
you
 
want
 
to
 
group
 
into
 
an
 
array
 
and
 
create
 
a
 
hot-spare
 
drive.
 
Using
 
express
 
configuration:
   
To
 
use
 
express
 
configuration,
 
complete
 
the
 
following
 
steps:
 
1.
   
In
 
the
 
ServeRAID
 
Manager
 
tree,
 
click
 
the
 
controller.
 
2.
   
Click
 
Express
 
configuration
.
 
3.
   
Click
 
Next.
 
4.
   
In
 
the
 
“Configuration
 
summary”
 
window,
 
review
 
the
 
information.
 
To
 
change
 
the
 
configuration,
 
click
 
Modify
 
arrays
.
 
5.
   
Click
 
Apply
;
 
when
 
you
 
are
 
asked
 
whether
 
you
 
want
 
to
 
apply
 
the
 
new
 
configuration,
 
click
 
Yes
.
 
The
 
configuration
 
is
 
saved
 
in
 
the
 
controller
 
and
 
in
 
the
 
physical
 
drives.
 
6.
   
Exit
 
from
 
ServeRAID
 
Manager
 
and
 
remove
 
the
 
CD
 
from
 
the
 
CD-RW/DVD
 
drive.
 
7.
   
Restart
 
the
 
server.
Using
 
custom
 
configuration:
   
To
 
use
 
custom
 
configuration,
 
complete
 
the
 
following
 
steps:
 
 
1.
   
In
 
the
 
ServeRAID
 
Manager
 
tree,
 
click
 
the
 
controller.
 
 
2.
   
Click
 
Custom
 
configuration
.
 
 
3.
   
Click
 
Next
.
 
 
4.
   
In
 
the
 
“Create
 
arrays”
 
window,
 
from
 
the
 
list
 
of
 
ready
 
drives,
 
select
 
the
 
drives
 
that
 
you
 
want
 
to
 
group
 
into
 
the
 
array.
 
 
5.
   
Click
 
the
 
(Add
 
selected
 
drives)
 
icon
 
to
 
add
 
the
 
drives
 
to
 
the
 
array.
 
 
6.
   
If
 
you
 
want
 
to
 
configure
 
a
 
hot-spare
 
drive,
 
complete
 
the
 
following
 
steps:
 
a.
   
Click
 
the
 
Spares
 
tab.
 
b.
   
Select
 
the
 
physical
 
drive
 
that
 
you
 
want
 
to
 
designate
 
as
 
the
 
hot-spare
 
drive,
 
and
 
click
 
the
 
(Add
 
selected
 
drives)
 
icon.
 
7.
   
Click
 
Next
.
 
 
8.
   
Review
 
the
 
information
 
in
 
the
 
“Configuration
 
summary”
 
window.
 
To
 
change
 
the
 
configuration,
 
click
 
Back
.
 
 
9.
   
Click
 
Apply
;
 
when
 
you
 
are
 
asked
 
whether
 
you
 
want
 
to
 
apply
 
the
 
new
 
configuration,
 
click
 
Yes
.
 
The
 
configuration
 
is
 
saved
 
in
 
the
 
controller
 
and
 
in
 
the
 
physical
 
drives.
 
10.
   
Exit
 
from
 
ServeRAID
 
Manager
 
and
 
remove
 
the
 
CD
 
from
 
the
 
CD-RW/DVD
 
drive.
 
11.
   
Restart
 
the
 
server.
Viewing
 
the
 
configuration
 
You
 
can
 
use
 
ServeRAID
 
Manager
 
to
 
view
 
information
 
about
 
RAID
 
controllers
 
and
 
the
 
RAID
 
subsystem
 
(such
 
as
 
arrays,
 
logical
 
drives,
 
hot-spare
 
drives,
 
and
 
physical
 
 
46
 
ThinkServer
 
RD120
 
Types
 
6444,
 
6445,
 
6446,
 
and
 
6447:
 
Installation
 
Guide