Symptom
 
Action
 
The
 
server
 
does
 
not
 
turn
 
off.
 
1.
   
Turn
 
off
 
the
 
server
 
by
 
pressing
 
the
 
power-control
 
button
 
for
 
5
 
seconds.
 
2.
   
Restart
 
the
 
server.
 
3.
   
If
 
the
 
server
 
fails
 
POST
 
and
 
the
 
power-control
 
button
 
does
 
not
 
work,
 
disconnect
 
the
 
power
 
cord
 
for
 
20
 
seconds;
 
then,
 
reconnect
 
the
 
power
 
cord
 
and
 
restart
 
the
 
server.
 
 
Attention:
  
In
 
a
 
dc
 
power
 
environment,
 
only
 
trained
 
service
 
personnel
 
other
 
than
 
Lenovo
 
service
 
technicians
 
are
 
authorized
 
to
 
connect
 
or
 
disconnect
 
power
 
to
 
the
 
dc
 
power
 
supply.
 
See
 
the
 
documentation
 
that
 
comes
 
with
 
each
 
dc
 
power
 
supply.
 
4.
   
If
 
the
 
problem
 
remains,
 
suspect
 
the
 
system
 
board.
 
The
 
OVER
 
SPEC
 
LED
 
on
 
the
 
light
 
path
 
diagnostics
 
panel
 
is
 
lit,
 
and
 
the
 
one
 
of
 
the
 
power
 
channel
 
LEDs
 
on
 
the
 
system
 
board
 
is
 
lit.
 
See
 
the
 
power
 
troubleshooting
 
table
 
in
 
the
 
Hardware
 
Maintenance
 
Manual
 
or
 
call
 
for
 
service.
 
The
 
server
 
unexpectedly
 
shuts
 
down,
 
and
 
the
 
LEDs
 
on
 
the
 
operator
 
information
 
panel
 
are
 
not
 
lit.
 
See
 
“Solving
 
undetermined
 
problems”
 
in
 
the
 
Hardware
 
Maintenance
 
Manual
.
  
Serial
 
port
 
problems
 
 
v
   
Follow
 
the
 
suggested
 
actions
 
in
 
the
 
order
 
in
 
which
 
they
 
are
 
listed
 
in
 
the
 
Action
 
column
 
until
 
the
 
problem
 
is
 
solved.
 
v
   
See
 
the
 
parts
 
listing
 
in
 
the
 
Hardware
 
Maintenance
 
Manual
 
to
 
determine
 
which
 
components
 
are
 
customer
 
replaceable
 
units
 
(CRU)
 
and
 
which
 
components
 
are
 
field
 
replaceable
 
units
 
(FRU).
 
v
   
If
 
an
 
action
 
step
 
is
 
preceded
 
by
 
“(Trained
 
service
 
technician
 
only),”
 
that
 
step
 
must
 
be
 
performed
 
only
 
by
 
a
 
trained
 
service
 
technician.
 
Symptom
 
Action
 
The
 
number
 
of
 
serial
 
ports
 
that
 
are
 
identified
 
by
 
the
 
operating
 
system
 
is
 
less
 
than
 
the
 
number
 
of
 
installed
 
serial
 
ports.
 
1.
   
Make
 
sure
 
that:
 
v
   
Each
 
port
 
is
 
assigned
 
a
 
unique
 
address
 
in
 
the
 
Configuration/Setup
 
Utility
 
program
 
and
 
none
 
of
 
the
 
serial
 
ports
 
is
 
disabled.
 
v
   
The
 
serial-port
 
adapter
 
(if
 
one
 
is
 
present)
 
is
 
seated
 
correctly.
2.
   
Reseat
 
the
 
serial
 
port
 
adapter,
 
if
 
one
 
is
 
present.
 
3.
   
Replace
 
the
 
serial
 
port
 
adapter,
 
if
 
one
 
is
 
present.
 
 
Chapter
 