Motorola T1/E1 用户手册

下载
页码 73
Canopy  T1/E1 Multiplexer 
 
 
 
 
 
 
September 2004 
 
 
 
 
 
 
     
      T1/E1 Multiplexer FPGA Version 3.4 
 
 
 
Page 44 of 73 
2.4.6  Configure Timing 
Before the timing may be configured, you need to determine the network timing scheme 
to be used.  You also need to identify the master and slave devices for the end-user PBX 
equipment.  
Procedure 13: Configuring timing using the CLI 
Action Steps 
Log in 
Press Enter. 
At the username prompt, enter admin. 
At the password prompt, enter password
Set master clock 
reference line  
NOTE: This is the master clock reference for all four T1/E1 lines.  
The default setting is T1/E1 Port 1. 
 
Enter set master clock reference line [1/2/3/4] 
where  
[1/2/3/4]
 represents T1/E1 ports 1 through 4. 
 
RESULT: The system responds 
Clk ref line; [1,2,3,4] 
 
Set backup clock 
reference line 
NOTE: This is the optional backup clock reference for all four T1/E1 lines.  The 
backup clock reference becomes active only when the master clock reference 
line is unavailable. The default setting is T1/E1 Port 2. 
 
Enter set secondary clock reference line [1/2/3/4] 
where  
[1/2/3/4]
 represents T1/E1 ports 1 through 4. 
 
RESULT: The system responds 
Backup clk ref line; [1/2/3/4] 
 