3.5  MEASUREMENTS FROM DIAGNOSTICS 
A unit-based comparison of diagnostic measurements is provided in 
Table 13: Comparison of diagnostic measurements 
Measurement Description Availability
Advantage 
Disadvantage 
Bit errors 
Logic errors in 
the bit stream 
Only out of 
service 
Best unit for 
point-to-point 
performance 
Requires that all traffic 
be test traffic (known 
data pattern) 
BPVs 
Pulses of the  
same consecutive
polarity 
In service 
or out of 
service 
Good for circuit
or repeater 
problems 
Meaningful for only 
metallic media, because 
some equipment corrects
BPVs 
Frame errors 
Incorrect values 
in the framing 
bit position 
In service 
or out of 
service 
Approximates 
bit error rate on
in-service basis
Evaluates only overhead
bits 
CRC errors 
Bit errors in a 
block of data 
In service 
or out of 
service 
98.4% bit error
rate accuracy 
Available with only ESF 
framing 
 
3.6  FIRMWARE UPGRADES 
Firmware upgrades are periodically made available to enhance performance or to add 
features and functionality to the Canopy T1/E1 Multiplexer. 
Procedure 29: Upgrading firmware 
To install new firmware on a Canopy T1/E1 Multiplexer, perform the following steps. 
1.  Close any other applications that are active on the PC. 
2.  From the main menu of the EMS, select Config
→Software Upgrade (shown in 
 on Page 
RESULT: The System Upgrade window opens, as shown in 
 
 
 
Figure 24: System Upgrade window 
 
Issue 3