3com NJ240FX 用户指南
![3com](https://files.manualsbrain.com/attachments/960452ff43b9899cbcffced60c87abf956e7967a/common/fit/150/50/f6ac125d7af2cf40fec58935fa6d4bf71457a57efe50bee91208a434f325/brand_logo.jpeg)
59
A
Troubleshooting the NJ240FX
If you encounter problems with the IntelliJack:
■
Verify the IntelliJack is receiving power by viewing the Power LED (it should be on). If
the Power LED is not on, make sure that:
the Power LED is not on, make sure that:
■
The local power supply is plugged into the IntelliJack and into a working
electrical outlet.
electrical outlet.
■
Verify the IntelliJack is connected to the network properly by viewing the Link LED (it
should be on). If the Link LED is not on, make sure the network cable:
should be on). If the Link LED is not on, make sure the network cable:
■
Is terminated properly. Refer to the connector manufacturer’s instructions for
terminating the cable. Be sure to test the connector and verify it is working.
terminating the cable. Be sure to test the connector and verify it is working.
■
Has a valid connection to the network.
■
Adheres to proper length and cabling specifications for your network.
■
The IntelliJack is configured for manual MDI. Be sure to use a straight-through cable.
If you want to use a cross-connect cable, you must change settings in the
Configuration Manager software.
If you want to use a cross-connect cable, you must change settings in the
Configuration Manager software.
Troubleshooting Matrix
Event/Message
Description
Solution
Power LED is not on
IntelliJack is not receiving
power
power
■
Ensure power supply is properly
connected.
connected.
■
Make sure the upstream switch is
configured and active
configured and active
Link LED is not on
IntelliJack has no connection
to the network
to the network
■
Make sure network cable is properly
terminated.
terminated.
■
Make sure the IntelliJack is connected
to the network.
to the network.
■
Make sure the cable is plugged into
the workgroup switch.
the workgroup switch.
■
Make sure the upstream switch is
configured and active
configured and active
Green LEDs on Ports 1-4
are not on
are not on
Network device has no
connection to IntelliJack
connection to IntelliJack
■
Make sure the cable is properly
connected to the network device.
connected to the network device.
■
Make sure the cable is firmly
connected to one of the four
IntelliJack ports labeled 1-4.
connected to one of the four
IntelliJack ports labeled 1-4.
■
Make sure the cable is a good
straight-through cable.
straight-through cable.