RuggedCom I800 用户手册

下载
页码 21
Installation 
2.2  Power Supply Wiring and Grounding 
 
R
atings
:
12
-2
4
V
, 2
A
P1
+
P1
-
GN
D
P2-
P2+
back 
front 
DC Input 1
DC Input 2
Chassis 
Ground 
Figure 5: DC Power supply and ground connections 
 
The low voltage DC power supply features reverse polarity protection and dual 
independent inputs, allowing the connection of two DC sources with the same 
nominal voltage to provide redundant power supplies. A list of power and ground 
connections follows in Table 3. 
 
Pin 
Function 
Connector 
P1+ 
DC Power Supply 1 positive terminal 
Phoenix connector 
P1- 
DC Power Supply 1 negative terminal 
Phoenix connector 
GND 
Power Supply Ground 
Phoenix connector 
P2- 
DC Power Supply 2 negative terminal 
Phoenix connector 
P2+ 
DC Power Supply 2 positive terminal 
Phoenix connector 
Chassis 
Ground 
Chassis Ground connection 
Screw terminal on chassis 
Table 3: Power Supply Connector Pinout 
 
NOTE: Terminals P1-, P2-, and GND are connected together internally. 
RuggedSwitch™
i800 family 
11 
RuggedCom®