RuggedCom I800 用户手册
Installation
2.4 RS232 Console Port Wiring
The RS232 Console Port is used for initially configuring the unit. The connection is
made using a DB9-Female to RJ45 console cable with the pin-outs listed in Table 5.
made using a DB9-Female to RJ45 console cable with the pin-outs listed in Table 5.
Pin 1
Pin 8
Figure 8: RS232 Female DCE pin-out
RuggedCom RS232 over RJ45 pin-out specification
Signal Name (PC is DTE)
DB9- Female
RJ45 Male
DCD – Carrier detect
1
2
RxD – Receive data (to DTE)
2
5
TxD – Transmit data (from DTE)
3
6
DTR – Data terminal ready
4
3
Signal GND
5
4
DSR – Data set ready
6
1*
RTS – Ready to send
7
8
CTS – Clear to send
8
7
RI – Ring Indicator
9
1*
Table 5: RS232 over RJ45 console cable pin-out
NOTE:
• This port is not intended to be a permanent connection
• This port is not intended to be a permanent connection
• The cable must be less than 2m (6.5 ft) in length.
• The following cross-connections are made inside the i800:
• The following cross-connections are made inside the i800:
o DSR / RI / DTR
o RTS / CTS
o RTS / CTS
• DCD
is
not connected.
RuggedCom® 14
RuggedSwitch™
i800 family