Chapter 7: Device Management 
 
 
173
 
KX2-832 and KX2-864 Standard and Extended Local Port Settings 
The KX2-832 and KX2-864 provides you with two local port options: the 
Standard Local port and the Extended Local port. Each of these port 
options is enabled and disabled from the Remote Console on the Port 
Configuration page or from the Local Console on the Local Port Settings 
page (see 
Configuring Dominion KX II Local Port Settings
 (on page 
169)).  
By default, the Standard Local port is enabled and the Extended Local 
port is disabled. If you would like to extend the reach of the local port, 
enable the Extended Local port and use a Cat5/5e/6 cable to connect to 
the DKX2-832 or DKX2-864 from a Paragon II UMT, EUST, UST or 
URKVMG.  
You must have Administrator privileges to configure these options. To 
access a port, you only need to enter your username and password 
once. You do not have to enter these credentials for each port you 
access. 
See the 
Specifications
 (on page 234) section for details on the devices 
supported by the Extended Local port, as well as distance specifications 
and supported CIMs. 
KX2-832 and KX2-864 Connection Limitations 
The Standard and Extended Local ports share access to a target. When 
both are enabled, the keyboard, video and mouse are shared between 
the Standard and Extended Local ports. Both will be connected to or 
disconnected from the target.   
When either the Standard or Extended Local ports is disabled, the 
keyboard, video and mouse for the ports will be disabled and a message 
is displayed you that the local ports have been disabled.