Raritan Engineering KX2-832 用户手册

下载
页码 321
Chapter 12: Command Line Interface (CLI) 
 
216
 
 
Setting Network Parameters 
Network parameters are configured using the interface command. 
admin > Config > Network > interface enable true if lan1 
ip 192.16.151.12 mask 255.255.255 gw 192.168.51.12
 
When the command is accepted, the device automatically drops the 
connection. You must reconnect to the device using the new IP address 
and the user name and password you created in the resetting factory 
default password section. 
Important: If the password is forgotten, the Dominion KX II will need 
to be reset to the factory default from the Reset button on the back 
of the Dominion KX II. The initial configuration tasks will need to be 
performed again if this is done. 
The Dominion KX II now has the basic configuration and can be 
accessed remotely via SSH, GUI, or locally using the local serial port. 
The administrator needs to configure the users and groups, services, 
security, and serial ports to which the serial targets are attached to the 
Dominion KX II. 
Note: Both IPv4 and IPv6 addresses are supported.   
 
CLI Prompts 
The Command Line Interface prompt indicates the current command 
level. The root portion of the prompt is the login name. For a direct admin 
serial port connection with a terminal emulation application, Admin Port 
is the root portion of a command. 
 
admin >
 
For TELNET/SSH, admin is the root portion of the command: 
 
admin > config > network >
 
 
CLI Commands 
• 
Enter admin > help. 
Command 
Description 
config 
Change to config sub menu. 
diagnostics 
Change to diag sub menu. 
help 
Display overview of commands.