Acer ALH-316ds/324ds 用户手册

下载
页码 21
4.1 Symptoms and Suggestions
Symptoms
Possible Reason
Suggestion
All LEDs are off.
The hub is not receiving 
1.Check if the AC power cord 
power.
plug is both securely fastened at 
the AC outlet and the hubs.
2.Contact you vender if still 
unworkable.
Fan Err. LED is
The fan is dead or works  1.Check your fan, maybe you 
blinking or down
abnormal
should have a new fan.
2.Contact the vender
Link LED of a
1.The UTP cable is 
1.Check the cable connection
connected port
not securely connected
is off.
2.The port is bad
2 Try to connect another port
3.If the other party is a 
3.Check if the network interface
PC, the network interface  card (NIC) were installed
card(NIC) could be not 
properly.
working
4.If the other party is a
4.Make sure ALH-316ds/324ds 
hub or LAN switch, the 
normal port is connected to the
connected ports signal 
other hub’s (or switch’s) uplink
could be cross-over
port is connected the other’s
normal port.
5.The UTP cable is
5.Try another normal cable.
broken, or it is cross-
overed cable.
100 LED is not lit 
The auto-negotiation 
1. Check if you force the
when connected to a 
function is failed between connection equipment in
100 NIC or 100 Hub 
ALH-316ds/324ds and the  specific mode. If, yes, then free
(but Link LED is lit.)
other part
it to auto-negotiation
2. Un-plug the UTP cable from
ALH-316ds/324ds and plug-in
again.
3.Check if the NIC is set to auto-
negotiation mode.
4.Check if the other hub is set to 
auto-negotiation mode
5. If the above steps does not 
work, it is an interoperability 
problem, contact your vender.
14
4.Trouble shooting
update ALH-316_324UM.qxd  11/10/99 8:42 AM  ›¶›– 1 4