RS900 Family Installation Guide 
 
3.1.3  RJ11 Port 
 
EoVDSL data ports allow connection using RJ11 male connectors. The figure below shows the 
RJ11 port pin-out and LEDs. On units with Universal EoVDSL ports the Master LED can be toggled 
on or off depending on whether the port is set as a Master or Slave. On units with Long-Reach 
EoVDSL ports the Master unit will have the LED permanently on while the Slave unit will have the 
LED permanently off.  
 
 
Figure 9 - RJ11 port pin-out and LEDs 
 
Pin 
Signal 
3 Ring 
4 Tip 
Table 3 - RJ11 port pin-out 
 
Status LED 
Colour 
Activity 
Comments 
On Master 
Mode 
Mode Green 
Off Slave 
Mode 
Solid Link 
Established 
Link / Act 
Green 
Blinking Tx 
Activity 
Table 4 - RJ11 port LED description 
3.1.4  Configuration & Setup 
 
If the units have Universal EoVDSL ports, use the software to configure one unit as a Master and 
the other as a Slave. If the units have a Long-Reach EoVDSL port, no Master/Slave software 
configuration is necessary since the ports will already be fixed as Master or Slave. Once configured 
as Master and Slave and connected together, the units will then attempt to achieve the maximum 
speed based on the line length and conditions. The unit’s link LED may flash on and off several 
times before settling on a final link speed and declaring the port up. For detailed configuration 
options please consult the Rugged Operating System (ROS) Software User Guide. 
Page 22 of 42 
© 2008 RuggedCom Inc. All rights reserved. 
 
Rev100