RuggedCom RS900 用户手册

下载
页码 42
RS900 Family Installation Guide 
 
 
6  Technical Specifications 
 
6.1  Operating Environment 
 
Parameter 
Range 
Comments 
Ambient Operating Temperature 
-40 to 85
°C 
Ambient Temperature as measured from a 30 cm radius 
surrounding the center of the enclosure. 
Ambient Storage Temperature 
-40 to 85
°C 
 
Ambient Relative Humidity 
5% to 95% 
Non-condensing 
Table 11 - Operating Environment 
 
6.2  Power Supply Specifications 
 
Power Supply Type 
Minimum 
Input 
Maximum 
Input 
Fuse 
Rating 
Isolation 
Maximum Power 
Consumption 
12 – 24 VDC 
10 VDC 
36 VDC 
3.15 (T) 
1.5 kV DC 
24 VDC 
18 VDC 
36 VDC 
3.15 (T) 
1.5 kV DC 
48 VDC 
36 VDC 
72 VDC 
3.15 (T) 
1.5 kV DC 
HI (125/250 VDC) 
1
 
HI (110/230 VAC) 
1
 
88 VDC 
85 VAC 
300 VDC 
265 VAC 
3.15 (T) 
4 kV AC   
5.5 kV DC 
10W 
Table 12 - Power Supply Specifications 
 
NOTES:   
1.  This is the same power supply for both AC and DC. 
2.  (F) Denotes fast-acting fuse, (T) denotes time-delay fuse. 
3.  For continued protection against risk of fire, replace only with same type and rating of fuse. 
 
6.3  Failsafe Relay Specifications 
 
Parameter 
Value 
Max Switching Voltage 
30VAC, 80VDC 
Rated Switching Current 
0.3A @ 30VAC 
1A @ 30VDC, 0.3A @ 80VDC 
Table 13 - Failsafe Relay Specification 
 
NOTES: 
1.  Resistive Load. 
2.  For Class-2 circuits only. 
 
 
Page 33 of 42 
© 2008 RuggedCom Inc. All rights reserved. 
 
Rev100