Monitor Lamp indicators
Managing the indicated problems
If a problem should occur with the projector, the indicators will inform you. Manage the indicated problems as
follow.
follow.
Attention
J
LAMP1/LAMP2 indicator
Lamp
indication
Information
Check point
Remedial measure
Lighting in red
Indicates the time
for replacing the
lamp unit.
for replacing the
lamp unit.
Did you notice a “REPLACE
z
LAMP” message on the screen
when turning on the projector
power supply?
when turning on the projector
power supply?
This lamp monitor lights up when the
z
lamp unit used hours have reached
2 800 hours (when [HIGH] is selected
as the [LAMP POWER] setting).
Request the dealer to replace the lamp
2 800 hours (when [HIGH] is selected
as the [LAMP POWER] setting).
Request the dealer to replace the lamp
z
unit.
Blinking in red
(once)
Lamp unit is not
installed.
installed.
Check the lamp unit
z
compartment.
Install the lamp unit.
z
When lamp unit is installed and still
z
having the indicator lights, contact to
the dealer.
the dealer.
Blinking in red
(3 times)
Error is detected
in the lamp circuit.
in the lamp circuit.
Did you turn the power back
z
on immediately after turning it
off?
off?
Wait until the lamp has cooled off, and
z
then turn on the power.
Some error has arisen in the
z
lamp circuit.
Check for fluctuation (or drop)
z
in the source voltage.
Turn off the MAIN POWER switch
z
using the procedure on page 40 and
consult the dealer.
consult the dealer.
Note
If no problem is found or the problem remains, do not turn on the projector. Instead contact your dealer.
z
Filter indicator (FILTER)
Temperature indicator (TEMP)
Lamp2 indicator (LAMP2)
Lamp1 indicator (LAMP1)
Power indicator
(STANDBY (R) / ON (G))