Panasonic PT-DW8300U 用户手册

下载
页码 129
Replacement
ENGLISH - 
111
Maintenance
 
J
Procedure of lamp unit replacement
Attention
When the projector is mounted in the ceiling, do not work directly under the projector or put your face close to the projector.
 
z
The lamp unit and the lamp unit cover must be attached correctly and securely. Failure to do so, the projector will not be 
 
z
turned on for the protection circuit.
If the lamp unit is not installed smoothly, remove it and then install it again. If it is pushed in forcibly, its connector may be 
 
z
broken.
Turn the main power OFF, following the 
1 ) 
the power plug from the AC power 
source, and wait for one hour or more. 
Then check that the lamp unit has 
cooled down. 
Turn the “lamp unit cover fixing 
2 ) 
screw” (1 piece) with a Phillips-head 
screwdriver until it is fully loosened, 
and then hold the “lamp unit cover” 
securely and open it in the direction of 
the arrow.
Use a Phillips screwdriver to loosen 
3 ) 
the “Lamp unit cover fixing screw” (4 
screws) for the lamp unit to be replaced 
until the screws turn freely. Hold the 
“Handle” of the “Lamp unit” and 
gently pull the lamp unit out from the 
projector.
Replace the new LAMP unit in correct 
4 ) 
direction.
Use a Phillips screwdriver to securely 
5 ) 
tighten the 2 “Lamp unit cover fixing 
screw” for each lamp unit.
Close the “lamp unit cover” and 
6 ) 
tighten the “lamp unit cover fixing 
screw” (1 piece) securely with a 
Phillips-head screwdriver in the 
reverse order to Step 2).
Note
When the lamp unit is replaced, the duration of usage 
 
z
time will be reset to “0”.
Lamp unit cover 
fixing screw
Lamp unit cover
Lamp unit fixing screws
Lamp unit 1
Handle
Lamp unit 2
Lamp unit 
installation guide
Groove for lamp unit installation guide
Groove for lamp unit installation guide