10     MW800 CPU Owner’s Manual                                                                                                                                                                                               
Low Temperature Conditions 
The device supports working hard disk conditions even if it’s turned off. When the 
ambient  temperature  drops  below  the  low  hard  disk  operational  limit,  an  internal 
heater will automatically adjust and maintain the working conditions (see Hard disk 
heating when device is off
 parameter in section 3) for pre-defined time.  
 
• 
If the CPU is turned on when Hard disk heating when device is off time-out 
has  not  expired  yet  and  the  hard  disk  temperature  is  within  the  operating 
range, the CPU will boot up immediately.   
 
• 
If the CPU is turned on when Hard disk heating when device is off time-out 
occurs and the hard disk temperature is below the low hard disk operational 
limit, the CPU will activate the internal heater and will boot up only when the 
hard  disk  temperature  returns  to  the  operating  range.  The  heating  process 
takes  some  time  that  can  be  optimized  (see  Heater  optimization  parameter 
in section 3); please wait until this process is completed. 
 
NOTE: If the power source is a 9VDC car battery (see Power source parameter in 
section 3), the device will not power up when the temperature range is below the low 
operational limit. 
 
High Temperature Conditions 
The device will be turned on only if an ambient temperature does not exceed the high 
operational limit.  
 
NOTE: In extreme conditions, the overall performance of the device (including boot 
up time and sustained operations) may be degraded. It will return to normal when the 
ambient temperature returns to the operating range.  
 
CAUTION:
 If overheating, do not turn on the device until it cools down. 
 
Discharged Vehicle Battery 
If the power source is a 13.8VDC car battery (see Power source parameter in section 
3), the device will normally power up when the voltage level exceeds 10.3VDC.  
 
If the power source is a 9VDC car battery (see Power source parameter in section 
3), the device will normally power up when the voltage level exceeds 9VDC. 
 
Shut Down 
This chapter describes methods to power off the CPU box in normal and extreme 
conditions.