Troubleshooting
Calibration Problems
6/30/06
105SL User Guide
11342L-001 Rev. A
Calibration Problems
 identifies problems with calibration, the possible causes, and the recommended 
solutions.
Table 14 • Calibration Problems
Problem
Possible Cause
Recommended Solution
Loss of printing 
registration on labels. 
Excessive vertical 
drift in top-of-form 
registration.
Improperly positioned media 
guides.
Ensure that the media guides are properly 
positioned.
Media type set incorrectly.
Set the printer for the correct media type 
(non-continuous or continuous). See 
Media loaded incorrectly or 
media sensor positioned 
improperly.
Reload the media and ensure that the sensor in 
use is properly positioned (see 
Dirty platen roller.
Clean the platen roller according to the 
instructions in 
Auto Calibrate failed.
Improperly loaded media or 
ribbon. 
Ensure that media and ribbon are loaded 
correctly. 
The sensors could not detect the 
media or ribbon. 
Manually calibrate the printer (see 
).
Sensors dirty or improperly 
positioned. 
Ensure that the sensors are clean and properly 