56Ploblem Solving, Maintenance, & Service
The I-Prime signal is sent over the parallel interface (pin 31) and will automatically
override any settings you have made using the front panel buttons. To eliminate this
problem, enter the program MENU (hold SHIFT button while pressing SEL/MENU
button) and change the I-Prime item (in the Parallel I/F group) to Invalid.
…the Print Quality and Character Pitch buttons on the front panel won’t work?
The Operator Panel Function item on the printer MENU can be used to disable these
buttons. If the printer is part of a customized system or if it is used by a number of
people, the system manager may have used this option to make sure the printer is
always set properly.
…static electricity causes the paper to stick?
In cold, dry weather, static charges can build up on continuous-form paper. This can
make the paper cling to the paper separator. If you have this problem during high-
volume printing jobs, try moving the single sheet paper guides on the separator to-
gether so that the paper rests on the guides rather than on the separator itself.
Maintenance
This section explains how to change ribbons, clear paper jams and clean your printer.
Replacing the Ribbon Cartridge
When  replacing  the  ribbon,  be  sure  to  use  only  ribbons  specifically  for  use  with
MICROLINE 720/721 printers. For best results,use genuine OKI ribbons.
1. Turn printer off.
2. Disengage and swing open access cover.
Caution!
  Be  careful  not  to  touch  the