•  Electrical Trouble Shooting 
User Manual Model 676 LOKPRINT® 
Electrical Trouble Shooting 
Power Up / Sign On / Communications 
 
Problem 
Probable Cause 
Corrective Action 
Machine fails to power up 
with no light present in 
the AC power switch. 
1) Incorrect power voltage. 
1) Confirm that the AC entry is configured for the 
line voltage intended to be applied to the 
machine.  Failure to do so can damage the 
machine's internal power supply.  Refer to the 
"Fuse Configuration".  
 
2) Lack of power to machine. 
2) Check that both ends of the power cord are 
plugged in securely. 
2A) Confirm that the outlet the machine is plugged 
into has power. 
 
3) Missing or blown fuse(s) 
3) Check that the fuse(s) located inside the AC 
entry are present and intact.  Replace as needed. 
Refer to the "Fuse Configuration".  
Machine fails to power up 
with light present in the 
AC power switch. 
1) Unconnected cable / connector 
inside machine.  
1) Power off and remove the power cord from the 
AC entry.  Remove the back cover and inspect 
the cables and connectors to and from the power 
supply.  Refer to the "Electrical System 
Schematic". 
 
2) Thermal Control Board 
unplugged from the Mother Board 
2) Power off and remove the power cord from the 
AC entry.  Remove the back cover and reseat the 
Thermal Control Board. 
Front panel displays no text 
or nothing at all. 
1) Front panel cable unplugged. 
1) Power off and remove the power cord from the 
AC entry.  Remove the back cover and inspect 
the cable and connectors to and from the front 
panel.  Refer to the "Electrical System 
Schematic".