Avery 676 用户手册

下载
页码 79
User Manual Model 676 LOKPRINT® 
Appendix C  •
••
•  53 
Printhead Installation and Removal Procedures 
Printhead removal procedure 
 
1) Loosen (2) 6-32 Phillips screws visible through holes in the upper print head 
holder.  Slide the head toward unwind end of printer. 
NOTE:  Screws are fitted with washers. 
2) Place your hand (with static gloves on) underneath the print line of the print head 
and pull down guiding screws through keyhole slots.  This will remove the print 
head assembly from the mount plate.  You may need to "help" the print head out 
by pushing on the heat sink with your left hand. 
3) Remove the two print head mount screws located on the top of the print head with 
a Phillips head screwdriver. 
4) Remove the old printhead carefully from the heat sink.
 
 
Printhead installation procedure 
 
1) Place the new print head onto the heat sink.   
2) Replace the two print head mount screws.  Be sure that the head is resting flat on 
the heat sink before tightening these screws. 
3) Replace the print head assembly in the printer, sliding screw / washer  (Paragraph 
1 - Printhead removal procedure) into the holes in the mount plate.  Make sure 
that the screw / washer slides all the way to the front of the holder.  Tighten 
screws. 
4) Reconnect the print head cable connectors, making sure that the connectors are 
seated tightly.   
NOTE: If the cable is not connected correctly, the print head will be destroyed when 
the machine is powered on.  Check to see that the cable is tight by observing 
from underneath the print head.  The cable’s connectors should be inside of 
the connectors located on the print head.