4-3
4.2 PARALLEL 
INTERFACE 
 
1.  Data input timing 
 
 
T5
T4
T3
T2
T1 
DATA0 to 7 
BUSY 
T6
T7
 
 
STROBE 
 
 
ACK 
 
 
 
 Min.
Max.
Unit
T1 0.1 
− 
µs 
T2 0.5 
− 
µs 
T3 0.5 
− 
µs 
T4 
− 0.5 µs 
T5 0 
− 
µs 
T6 0.5 
− 
µs 
T7 
− 1.0 µs 
 
 
4.3 SERIAL 
INTERFACE 
 
1. Hardware 
control 
The RTS signal (Low or High) controls the transmission of the data from a host computer. 
 
When the data stored in the input buffer of the printer exceeds 4,046 bytes, the RTS signal turns 
Low. 
Once the RTS signal turns Low, the host computer stops to transmit the data. 
If the data stored in the input buffer of the printer falls below 3,995 bytes, the RTS signal turns 
High. 
Once the RTS signal turns High, the host computer resumes transmitting the rest of the data. 
 
∗ When the printer fails (for example, paper-out), the RTS signal also turns Low. 