Seiko Instruments DPU-30 用户手册

下载
页码 84
 
5-8
SI 
Double–Width Printing Mode Clear 
 
Code 
 
 
0F
16
 
Function 
 
  Clears the double
−width printing. 
 
 
CAN Cancel 
 
Code 
 
 
18
16
 
Function 
 
  Clears the print buffer. 
Details 
 
 
• After executing this command, a head of a line is set as a starting position of 
printing. 
 
 
ESC S n1 n2 n3 n4 Bitimage 
Graphic 
 
Code 
 
 
1B
16
 
+ 53
16
 
+ n1 + n2 + n3 + n4 + [DATA] 
Domain of 
function 
 
  30
16
 
≤ n1, n2, n3, n4 ≤ 39
16
 
 “0001” 
≤ “n1 n2 n3 n4” ≤ “1023” 
≤ d ≤ 255 (graphic data) 
 
  
Function 
 
The number of data specified in ASCII code n1, n2, n3 and n4 are specified as a 
Bitimage. 
Example: Case that 192 Bitimages are specified 
1B
16
 
+ 53
16
 
+ “0192” + . . . . . . . . .   
[192 DATA] 
 
  
Details 
 
 
• The code outside the domain of function processes the data as the 1-byte data 
thereafter. 
• If the dots are specified outside the printing area, the data is ignored. 
• The data deployment position is set in accordance with the predefined starting 
position of the data deployment. 
• This command is affected by the inverse printing. 
• If the next Bitimage Specify command is received at the occurrence of the line 
overflow, the data of the previous line stored in the print buffer is printed. The line 
overflow is determined according to the number of dots described below. 
−  Mode 1: Determined as the line overflow if the number of dots exceeds 276. 
−  Mode 2: Determined as the line overflow if the number of dots exceeds 332. 
• Refer to the figure shown below for how the data is deployed.