Citizen Systems CBM-230/231 用户手册

下载
页码 59
CBM-230/231 User’s Manual
CITIZEN
23
 6.3 Input / Output Signals
  
   6.3.1 Input / Output Signals
     (1) Input signals to the printer
l  DATA
: This is an 8-bit parallel signal (Positive logic)
l  STB
: This is a strobe signal to read in 8-bit data (Negative logic)
l  RESET 
: This signal resets the entire printer (Negative logic) 1 ms or more
     (2) Output signals from the printer
l  ACK       
: This is an 8-bit data request signal. Pulse signal output at the end of
  the BUSY signal (Negative logic)
l  BUSY          : This signal indicates the BUSY state of the printer. Enter new data when it is
  at LOW. (Positive logic)
l  FAULT  
 : This signal is set to low when the printer has an alarm.
  When this is done, all control circuits in the printer stop.   (Negative logic)
l  PE 
 : This signal is output when the printing paper has run out or is running out.
  (Positive logic)
l  Drawer switch output : This signal is set to HIGH when the switch is opened, and to LOW when shorted.
     (3) Power signals
l  +5VDC : This is a 5 V output pulled up at a 3.3 k Ohm resistor.
l  GND   : This is a common ground on the circuits.