Allied Telesis AT-9900 用户手册

下载
页码 232
24
enable epsr debug
Software Reference
enable epsr debug
Syntax
ENAble EPSR={epsr-name|ALL} DEBug={INFo|MSG|PKT|STAte|ALL} 
[OUTput=CONsole] [TIMEOut={1..4000000000|NONE}]
Description
This command enables debugging for either the selected EPSR instance, or all 
EPSR instances.
 Examples
To enable all debugging modes on the EPSR instance called blue, use the 
command:
ena epsr=blue deb=all
Related Commands
Parameter
Description
EPSR
The EPSR instance whose debugging is to be enabled.
Default: no default
epsr-name
The name of the EPSR instance. This can be a character 
string, 1 to 15 characters long. Valid characters are 
uppercase letters (A-Z), lowercase letters (a-z), digits (0-9), 
the underscore character ("_"), the hyphen character ("-"). 
The epsr-name cannot be ALL.
ALL
All EPSR instances.
DEbug
The debugging modes to be enabled.
Default: no default.
INFo
General information about the EPSR instance selected.
MSG
Decoded display of received and transmitted EPSR frames.
PKT
Raw ASCII display of received and transmitted EPSR frames.
STAte
EPSR state transitions.
ALL
All debug options. 
OUTput
When this parameter is set to console, all debugging information will be 
sent to the console. By default, the debugging data is sent to the port that 
received the enable epsr debug command. Use this option if the enable 
epsr debug 
command is used in a script, because a script is not received 
on a port.
TIMEOut
The number of seconds during which debugging is enabled on the 
specified EPSR instances. Limiting the debugging period reduces the risk of 
overloading the switch with debugging information. This value set in this 
command overrides all previous EPSR debugging timeout values for the 
specified EPSR instances, even if they were specified for other debugging 
modes.
Default: the most recent timeout value set in an enable epsr debug 
command for the given EPSR instance, or none if none had been set.